KABA MAUER Code-Combi B 82132
Electronic combination lock with dead bolt and mechanical redundancy for safes CEN III-V.
Approx. 1 million variations. Standard footprint.
The mechanical redundancy offers maximum reliability: by removing the bar handle the hidden keyhole can be exposed and the lock can be opened with the double-bitted key.
The lock features power saving solenoid technology. Under defined conditions it is possible to achieve approx. 30,000 opening operations with one battery.
EV1 anodised aluminium input unit.
Approvals/Certificates
EN 1300, ECB-S, VdS class 2, GOST class B, IMP class B, ICECON class B
Codes
2 user codes (6 digits) 1 dual mode (2 x 6 digits) 1 user code (1 x 6 digits)
1 dual mode (2 x 6 digits)
Code functions
Single mode (1 x 6 digits)
Dual mode (2 x 6 digits)
Delegated dual mode (1 x 6 digits or 2 x 6 digits)
Wrong try lockout after 3 false codes (1, 2, 4, 8, max. 16 minutes)
Time lock functions
Time delay, 0-99 minutes
Opening window, 1-9 minutes
General functions
Low voltage detection
Acoustical and optical operation support, manipulation indication
Power supply
1 x 9 volt block battery (not included in delivery)
Lock
Die-cast lock case and bolt
Electromagnetic bolt release
Bolt with 2 M4 threads, throw 12 mm
Mechanical redundancy by lever system: 11 levers, double-bitted key retained when in open position
Admissible mounting positions
Right hand/left hand lock (upside down mounting), opening clockwise
NB: Not all mounting positions are admissible for all input units.